GE 1505-3272-000 Neonatal Flow Sensor For Ventilator

GE 1505-3272-000 Neonatal Flow Sensor For Ventilator

share
  • Detail
  • Parameters

GE 1505-3272-000 Neonatal Flow Sensor For Ventilator



Brief Description

The GE Healthcare 1505-3272-000 is an official OEM replacement Neonatal Flow Sensor designed specifically for advanced respiratory care. It is precision-engineered to integrate seamlessly with critical care ventilation systems, ensuring high accuracy and reliability when managing the delicate respiratory needs of neonatal patients.



►Features

  • Precision Flow Detection: Measures extremely small tidal volumes and rapid flow rate changes characteristic of neonatal respiration with high accuracy.

  • Real-Time Monitoring: Continuously tracks breath-by-breath respiratory parameters and feeds data back to the ventilator system to maintain optimal patient-ventilator synchrony.

  • Ventilator Triggering Support: Enhances sensitivity for patient-initiated breaths, minimizing the work of breathing for fragile neonates.

  • System Integration & Safety: Works directly with the GE Carescape™ R860 platform to support advanced pulmonary mechanics monitoring, waveform analysis, and safety alarm management.



Specification


BrandGE
Model1505-3272-000
ConditionOriginal & new
SeriesNeonatal Flow Sensor
Compatible Ventilation SystemGE Carescape™ R860 Ventilator Series (v1)
Patient CategoryNeonatal
ApplicationCritical Care / Intensive Care Unit (ICU)
MOQ1 Piece
PackageCarton / Standard Export Packing
TransportationDHL, FedEx, UPS, etc.
In StockYes
PriceAccept Negotiation




FAQ



How should I troubleshoot a flow sensor error on the Carescape R860?

  • A: If the ventilator displays a flow sensor error or failure:

    1. Check that the sensor cable connections are secure and properly plugged into the ventilator.

    2. Inspect the sensor tubing for moisture, kinks, or blockages.

    3. Perform a zero-calibration or sensor check as outlined in the GE Carescape R860 operator's manual.

    4. Replace the sensor if the error persists or if it has exceeded its operational lifespan.




More service


Spare parts for Ventilator:original flow sensor,flow sensor connection cable ,OXYGEN SENSOR,HEPA FILTER , RESPIRATORY HUMIDIFIER ,POWER SUPPLY,EXHALATION VALVE,Battery module, Flow Sensor,Main boad ,Display/LCD Screen,etc.



About Us


JDP is the global provider of medical equipment and medical equipment repair service, as well as offering spare parts. We focus on repair and repair training for monitor, Flexible & Rigid Endoscope, ultrasound, camera system, dynamical system and surgical instrument.


Shipping and packing
All products will be tested and sterilized for free, perfectly packed to ensure the safety of the goods, strictly in accordance with international export rules. We send to worldwide via EMS, DHL, FEDEX or other express, based on your choice.



Brand
GE
Model
1505-3272-000
Series
Neonatal Flow Sensor
Condition
Original New